Commercial PTO Mobile Generators
Designed for tough environments giving the most power in minimal space.
Why PTO?
Harrison's PTO shaft driven generators are engineered for durability, built to last even in the toughest environments providing maximum heavy duty power at the scene without the need for a secondary engine. Designed for ease of installation by providing a weatherproof remote-mounted electrical box.
Sustainability
Save the planet! Keep the air we breathe clean while keeping your people safe on the job by reducing CO2 emissions.
Reliability
Built to last, even in the toughest environments providing a longer life cycle with less maintenance. Even starts in cold weather or after limited use.
Smaller Footprint
Approximately 50% smaller in size and 50% less weight when compared to bulky gas generators. They are designed to fit in tight spaces, making it easier to operate without the need for a secondary engine.
Standard
Performance/Features
- Marine coated for harsh environments (by design)
- Lifetime lubricated bearings
- Instant AC power
- Maintenance-free design
- Precise frequency controls keep output regulated within two percent
Options/Accessories
- Optional digital meter
Classifications
- Class "H" Insulation
TEFC IP54 Weatherproof Generator
For even more protection, opt for our Totally Enclosed Fan Cooled (TEFC) generator. This robust design enables seamless operations in even harsher environments, including high-water applications, heavy dust exposure, and contact with corrosive substances and fumes. Used when IP54 protection is requested.
Spec Text
- The generator shall be one (1) Harrison PTO Series – Shaft Driven Generator.
- The generator shall be designed and assembled by a company with no less than 20 years of experience manufacturing mobile AC generators.
- The generator shall be available in both 50 or 60hz.
- The generator shall be available in single and 3 phase.
- The generator shall have 4-foot leads to a remote electrical box to house the AVR and terminal block.
- The generator shall use an industrial-type alternator with heavy-duty bearings and a brushless design.
- The generator shall offer a meter to monitor the frequency, voltage, and amperage of each leg.
- The generator shall utilize a digital meter to display:
- Output Frequency
- Output Voltage
- Output Amperage For Each Leg
- Hydraulic Oil Temperature
- Generator Operating Hours
- High Temperature Alert
- Current Out of Range Alert
- Frequency Out of Range Alert
- The generator shall be capable of producing the full nameplate power when driven from the vehicle PTO at the proper speed.
- The generator shall have total+ winding protection.